Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25.10.2012 to 06.11.2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Justification for type of information:
Data is from experimental study report
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Principles of method if other than guideline:
Lowest temperature determined at which substance vaporizes to form an ignitable mixture in air
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
> 400 °C
Atm. press.:
955 hPa
Interpretation of results:
other: not classified
Remarks:
based on CLP criteria
Conclusions:
The flash point for test chemical by the closed cup method was determined to be greater than 400 degC at 955 hPa atmospheric pressure.
Executive summary:

The experimental value of flash point for test chemical by the closed cup method was determined to be greater than 400 degC at 955 hPa atmospheric pressure.

Description of key information

The experimental value of flash point for test chemical by the closed cup method was determined to be greater than 400 degC at 955 hPa atmospheric pressure.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
400 °C

Additional information

The experimental value of flash point for test chemical by the closed cup method was determined to be greater than 400 degC at 955 hPa atmospheric pressure.