EC number: 239-510-5 | CAS number: 15484-80-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Description of first aid measures
If inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration.
In case of skin contact: Wash off with soap and plenty of water.
In case of eye contact: Flush eyes with water as a precaution.
If swallowed: Never give anything by mouth to an unconscious person. Rinse mouth with water.
Most important symptoms and effects, both acute and delayed:
The most important known symptoms and effects are described in the labelling (see section
2.2) and/or in section 11 of SDS.
Indication of any immediate medical attention and special treatment needed: No data available
Fire-fighting measures
Extinguishing media
Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture: Carbon oxides
Advice for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.
Further information: No data available
Accidental release measures
Personal precautions, protective equipment and emergency procedures: Avoid breathing vapours, mist or gas.
For personal protection see section 8 of the SDS.
Environmental precautions: Do not let product enter drains.
Methods and materials for containment and cleaning up: Keep in suitable, closed containers for disposal.
Reference to other sections: For disposal see section 13 of SDS.
Handling and storage
Precautions for safe handling
Normal measures for preventive fire protection.
For precautions see section 2.2. of the SDS.
Conditions for safe storage, including any incompatibilities: Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Storage class (TRGS 510): 12: Non Combustible Liquids
Specific end use(s): Apart from the uses mentioned in section 1.2 Of the SDS no other specific uses are stipulated.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control parameters
Components with workplace control parameters
Contains no substances with occupational exposure limit values.
Exposure controls: Appropriate engineering controls
General industrial hygiene practice.
Personal protective equipment
Eye/face protection: Use equipment for eye protection tested and approved under appropriate
government standards such as NIOSH (US) or EN 166(EU).
Skin protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove
removal technique (without touching glove's outer surface) to avoid skin contact
with this product. Dispose of contaminated gloves after use in accordance with
applicable laws and good laboratory practices. Wash and dry hands.
Body Protection: Impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific
workplace.
Respiratory protection: Respiratory protection not required. For nuisance exposures use type OV/AG (US) or
type ABEK (EU EN 14387) respirator cartridges. Use respirators and components
tested and approved under appropriate government standards such as NIOSH (US)
or CEN (EU).
Control of environmental exposure: Do not let product enter drains.
Stability and reactivity
Reactivity: No data available
Chemical stability: Stable under recommended storage conditions.
Possibility of hazardous reactions: No data available
Conditions to avoid: No data available
Incompatible materials: Strong oxidizing agent
Hazardous decomposition products
Hazardous decomposition products formed under fire conditions. - Carbon oxides
Other decomposition products - No data available
In the event of fire: see section 5 of the SDS
Disposal considerations
Waste treatment methods
Product: Offer surplus and non-recyclable solutions to a licensed disposal company.
Contaminated packaging: Dispose of as unused product.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.