Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
GLP compliance:
no
Other quality assurance:
other: ISO 9001-2008
Type of method:
Laser scattering/diffraction
Type of particle tested:
agglomerate
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
427.7 µm
Geometric standard deviation:
392.4
Percentile:
D90
Mean:
991.4 µm
Remarks on result:
other: st. dev. not given
Percentile:
D50
Mean:
317.8 µm
Remarks on result:
other: st. dev. not given
Percentile:
D10
Mean:
24.85 µm
Remarks on result:
other: st. dev. not given

Note that a small portion of the sample is out of the measurement range ofthe instrument.

Conclusions:
The median of mass distribution of the test ítem is 427,7 µm

Description of key information

The particle size determination is done by means of laser diffraction analysis.


The mass median diameter of the particles determined by laser diffraction analysis is 427,7 μm.

Additional information