Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid non flammable in air, e.g. no flash point up to 200°C
other:
Justification for type of information:
The substance is not possible to isolate from water.
Attempts to dry led to apparent decomposition with release of ammonia / amines at < 100 C (before boiling). there was no indication of exotherm.
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
GLP compliance:
no
Specific details on test material used for the study:
Liquid form used for assessment
No method found to remove water without decomposition and loss of ammonia
Physical state at 20°C and 1013 hPa:
liquid
Form:
liquid: viscous
Colour:
Pale coloured viscous liquid
Substance type:
organic

Note that this material contains water.

It is very likely solid if water could be removed.

At the time of dossier preparation, no suitable method had been found that allowed removal of water without decomposition.

Conclusions:
Note that this material contains water.
It is very likely solid if water could be removed.
At the time of dossier preparation, no suitable method had been found that allowed removal of water without decomposition.

Data source

Materials and methods

Results and discussion