Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 248-813-1 | CAS number: 28065-97-6
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 28 Apr 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 017
- Report date:
- 2017
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Version / remarks:
- adopted Oct 2017
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Hessisches Ministerium für Umwelt, Klimaschutz, Landwirtschaft und Verbraucherschutz, Wiesbaden, Germany
Test material
- Reference substance name:
- Oleic acid, compound with (Z)-octadec-9-enylamine (1:1)
- EC Number:
- 248-813-1
- EC Name:
- Oleic acid, compound with (Z)-octadec-9-enylamine (1:1)
- Cas Number:
- 28065-97-6
- Molecular formula:
- C34H69NO2 C36H67NO2 C36H69NO2 C36H71NO2 C36H73NO2
- IUPAC Name:
- oleic acid, compound with (Z)-octadec-9-enylamine (1:1)
Constituent 1
Test animals / tissue source
- Species:
- cattle
- Strain:
- not specified
- Details on test animals or tissues and environmental conditions:
- SOURCE OF COLLECTED EYES
- Source: AB Schlachthof GmbH & Co. KG, 63739 Aschaffenburg, Germany
- Characteristics of donor animals: at least 9 month old donor cattle
- Storage, temperature and transport conditions of ocular tissue: the isolated eyes were stored in HBSS containing 1% (v/v) Penicillin/Streptomycin (100 Units/mL penicillin and 100 µg/mL streptomycin) in the cooled slaughter-house until transportation on the same morning to the laboratory using a Styrofoam box.
- Time interval prior to initiating testing: the corneas were isolated on the same day after delivery of the eyes.
- indication of any existing defects or lesions in ocular tissue samples: all eyes were carefully examined macroscopically for defects. Those presenting defects such as vascularization, pigmentation, opacity and scratches were discarded.
- Indication of any antibiotics used: 1% (v/v) Penicillin/Streptomycin (100 Units/mL penicillin and 100 µg/mL streptomycin)
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- TEST MATERIAL
- Amount(s) applied: 0.75 mL
NEGATIVE CONTROL
- Amount(s) applied: 0.75 mL
POSITIVE CONTROL
- Amount(s) applied: 0.75 mL
- Purity: 99% - Duration of treatment / exposure:
- 10 min at 32 ± 1 °C
- Duration of post- treatment incubation (in vitro):
- 2 h at 32 ± 1 °C
- Number of animals or in vitro replicates:
- triplicates for each treatment and control groups
- Details on study design:
- SELECTION AND PREPARATION OF CORNEAS
The cornea was carefully removed from the eye using scalpel and rounded scissors. A rim of about 2 mm of tissue (sclera) was left for stability and handling of the isolated cornea. Each isolated cornea was mounted in a specially designed cornea holder, which consists of anterior and posterior compartments, which interface with the epithelial and endothelial sides of the cornea, respectively.
QUALITY CHECK OF THE ISOLATED CORNEAS
For equilibration, the corneas in the holder were incubated in a vertical position for about one hour at 32 ± 1 °C in a water-bath. At the end of the incubation period, the basal opacity was determined (t0). The basal opacity of all corneas was recorded. Each cornea with basal opacity value > 7 was discarded.
APPLICATION DOSE AND EXPOSURE TIME
Each isolated cornea was mounted in a specially designed cornea holder, which consists of anterior and posterior compartments, which interface with the epithelial and endothelial sides of the cornea, respectively. The endothelial side of the cornea was positioned against the sealing ring (O-ring) of the posterior part of the holder. The cornea was gently flattened over the O-ring but stretching was avoided. The anterior part of the holder was positioned on top of the cornea and fixed in place with screws. Both compartments of the holder were filled with incubation medium. The posterior compartment was filled first to return the cornea to its natural convex position. Care was taken to assure no air bubbles were present within the compartments. The cornea were incubated in a horizontal position at 32 ± 1 °C 10 min in the water-bath.
REMOVAL OF TEST SUBSTANCE
- Number of washing steps after exposure period: The test substance was rinsed off from the application side with saline.
- POST-EXPOSURE INCUBATION: at 32 ± 1 °C for further two hours in a vertical position
METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: The opacitometer determines changes in the light transmission passing through the corneae, and displays a numerical opacity value. The opacitometer OP_KiT opacitometer (Electro Design, 63-Riom France) was calibrated as described in the manual and the opacity of each of the corneas was determined by reading each holder placed in the photoreceptor compartment for treated cornea.
- Corneal permeability: passage of sodium fluorescein dye measured with the aid of a microtiter plate reader (OD490)
SCORING SYSTEM: In Vitro Irritancy Score (IVIS)
DECISION CRITERIA:
Test substance with an IVIS > 55 was regarded as severe irritant/corrosive and labelled Category 1.
Test substance with an IVIS ≤ 3 was regarded as non-irritant and labelled in no category.
Test substance with an IVIS > 3; ≤ 55: no prediction can be made.
Results and discussion
In vitro
Results
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- mean value of 3 corneae
- Value:
- 0.9
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- With the negative control (saline) neither an increase of opacity nor permeability of the corneas could be observed (mean IVIS = 0.75).
The positive control (2-Ethoxyethanol) was tested undiluted and showed clear opacity and distinctive permeability of the corneas (mean IVIS = 76.00) corresponding to a classification as serious eye damaging (CLP/EPA/GHS (Cat 1)).
Relative to the negative control, the test item did not cause an increase of the corneal opacity or permeability. The calculated mean IVIS was 0.90 (threshold for serious eye damage: IVIS > 55).
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: yes, the results in opacity and permeability values are less than the established upper limits for background opacity and permeability values for bovine corneae treated with the respective negative control.
- Acceptance criteria met for positive control: yes, the IVIS falls within two standard deviations of the current historical mean.
Any other information on results incl. tables
Table 1: Results after 10 min exposure time
Test Group |
Opacity value = Difference (t130-t0) of Opacity |
Permeability at 490 nm (OD490) |
IVIS |
Mean IVIS |
Proposed in vitro Irritancy Score |
||
|
|
Mean |
|
Mean |
|
|
|
Negative Control |
0 |
0.00 |
0.050 |
0.050 |
0.75 |
0.75 |
Not categorized |
0 |
0.051 |
0.77 |
|||||
0 |
0.048 |
0.72 |
|||||
Positive Control |
67.00* |
0.896* |
80.45 |
76.00 |
Category 1 |
||
56.00* |
1.093* |
72.40 |
|||||
65.00* |
0.677* |
75.16 |
|||||
Test substance |
0.00* |
0.045* |
0.68 |
0.90 |
Not categorized |
||
0.00* |
0.090* |
1.36 |
|||||
0.00* |
0.043* |
0.65 |
*corrected values
Table 2: Historical control data (Values of 116 studies with liquid test items performed from February 2015 (calendar week 7) to January 2017)
Positive Control | Negative Control | |
Mean IVIS | 83.61 | 1.03 |
Standard Deviation IVIS | 11.75 | 0.31 |
Range of IVIS | 56.25 – 113.06 | 0.56 – 2.38 |
Mean Opacity t130min | 65.75 | 0.04 |
Standard Deviation | 14.56 | 0.20 |
Opacity t130min | ||
Range of Opacity t130min | 26.00 – 112.00 | -0,33 – 1.00 |
Mean Permeability | 1.23 | 0.07 |
Standard Deviation Permeability | 0.39 | 0.01 |
Range of Permeability | 0.32 – 2.09 | 0.05 – 0.09 |
Applicant's summary and conclusion
- Interpretation of results:
- other: CLP/EU GHS criteria not met, no classification required according to Regulation(EC) No. 1272/2008
- Conclusions:
- Under the conditions of this test, the test substance did not cause an increase of the corneal opacity or permeability. The calculated mean in vitro irritancy score was 0.90 in the in vitro Bovine Corneal Opacity and Permeability Test. Therefore, the test substance does not require classification for eye irritation or serious eye damage.
CLP: not classified
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.