Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: This study does not follow normalised testing guideline and GLP, but was performed according to an acceptable method.
Reason / purpose for cross-reference:
reference to same study
Qualifier:
no guideline followed
Principles of method if other than guideline:
Laser diffraction particle size analysis was applied on a dispersion of the powder in isopropanol. Six measurements were performed according to GRAN-99001 (internal method).
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2000 standard.
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
20.2 µm
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
3.3 µm
St. dev.:
0.06
Percentile:
D50
Mean:
8.4 µm
St. dev.:
0
Percentile:
D90
Mean:
21.5 µm
St. dev.:
0.9

The table below summarizes the individual results, the mean value and the standard deviation for the mean diameter, D50 (median), the D10 and D90 percentiles and the MMAD estimated by assuming that the particles are spherical.

 

 

Mean diameter (µm)

D50 (µm)

D10 (µm)

D90 (µm)

MMAD (µm)

Trial 1

12.5

8.4

3.3

22.3

20.6

Trial 2

12.3

8.4

3.3

21.8

20.2

Trial 3

12.0

8.4

3.4

20.5

19.7

Mean value

12.3

8.4

3.3

21.5

20.2

Standard deviation

0.3

<0.1

<0.1

0.9

0.4

 

Conclusions:
The mean D50 of potassium cryolite was found to be 8.4 µm.
Executive summary:

Laser diffraction particle size analysis was applied on a dispersion of the powder in 2-butanol. Three measurements were performed.

The particle size distribution is summarised as follows:

 

Mean diameter

(μm)

D50

(μm)

D10

(μm)

D90

(μm)

MMAD

(μm)

Mean value

12.3

8.4

3.3

21.5

20.2

Standard deviation

0.3

<0.1

<0.1

0.9

0.4

Description of key information

The mean D50 of potassium cryolite was found to be 8.4 µm.

Additional information

One reliable key study is available for this endpoint. Laser diffraction particle size analysis was applied on a dispersion of the powder in 2 -butanol. Six measurements were performed. The particle size distribution is summarised as follows:

 

Mean diameter

(μm)

D50

(μm)

D10

(μm)

D90

(μm)

MMAD

(μm)

Mean value

12.3

8.4

3.3

21.5

20.2

Standard deviation

0.3

<0.1

<0.1

0.9

0.4