Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures:

- General information:

In all cases of doubt, or when symptoms persist, seek medical advice.

In case of unconsciousness place person in the recovery position. Never give anything by mouth.

- After inhalation:

Remove to fresh air.

Keep patient warm and at rest.

- After skin contact:

Remove contaminated clothing immediately. Wash skin thoroughly with soap and water or use recognised

skin cleanser. Do NOT use solvents or thinners.

- After eye contact

Irrigate copiously with clean, fresh water for at least 15 minutes, holding the eyelids apart. Remove contact

lenses. Obtain medical attention.

- After swallowing

Do NOT induce vomiting. Obtain medical attention.

- Most important symptoms and effects, both acute and delayed

No further relevant information available.

- Indication of any immediate medical attention and special treatment needed

No further relevant information available.

Fire-fighting measures

- Extinguishing media:

Suitable extinguishing agents: Alcohol resistant foam, CO2, powders, water spray

For safety reasons unsuitable extinguishing agents: Water jet

- Special hazards arising from the substance or mixture:

Appropriate breathing apparatus may be required.

Cool closed containers exposed to fire with water

- Advice for firefighters:

Protective equipment: No special measures required

Additional information: Collect run-off from fire fighting

Accidental release measures

- Personal precautions, protective equipment and emergency procedures:

Ventilate the area.

- Environmental precautions:

Do not allow to enter drains. If the product contaminates rivers and lakes or sewers inform respective authorities.

- Methods and material for containment and cleaning up:

Contain and collect spillage with non-combustible absorbent material (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local regulations. Clean preferably with a detergent. Avoid use of solvents.

Handling and storage

- Precautions for safe handling:

Avoid inhalation of vapour. Smoking, eating and drinking should be prohibited in application area. For personal protection see Section 8 of the SDS. Comply with health and safety at work laws. Avoid concentrations higher than the occupational exposure limits (see Section 8 of the SDS), if applicable.

- Conditions for safe storage, including any incompatibilities:

Requirements to be met by storerooms and containers:

Keep container tightly closed. No smoking. Containers which are opened must be carefully released and kept upright to prevent leakage.

- Further information about storage conditions:

Always keep in containers of the same material as the original one. Store in a dry, well ventilated place. Keep away from heat and direct sunlight. Store in accordance with the particular national regulations concerning water pollution. Note instructions on the label.

- Specific end use(s): No further relevant information available.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not classified according to transport regulations for dangerous goods
Shippingopen allclose all
Labels:
Not classified according to transport regulations for dangerous goods
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not classified according to transport regulations for dangerous goods
Shippingopen allclose all
Labels:
Not classified according to transport regulations for dangerous goods
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not classified according to transport regulations for dangerous goods
Shipping information
Proper shipping name and description:
Not classified according to transport regulations for dangerous goods
Chemical name:
Not classified according to transport regulations for dangerous goods
Labels:
Not classified according to transport regulations for dangerous goods
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not classified according to transport regulations for dangerous goods
Shipping information
Proper shipping name and description:
Not classified according to transport regulations for dangerous goods
Chemical name:
Not classified according to transport regulations for dangerous goods
Labels:
Not classified according to transport regulations for dangerous goods
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

- Additional information about design of technical systems:

If relevant apply technical measures to comply with the occupational exposure limits. This can be by a good general extraction and-if practically feasible, be achieved by local exhaust ventilation.

- Control parameters

Components with critical values that require monitoring at the workplace:

Numerical data - if specified - are taken from the valid national lists.

Exposure controls

- Breathing equipment:

The use of respiratory protective measures, such as masks with filters for organic Vapours and dusts / mistsare, in the absence of appropriate technical equipment, necessary for the protection of the employee. If exposure is above the exposure limit, then an appropriate, approved respirator must be worn. Please refer to the appropriate EU standard 14387.

- Protection of hands:

For prolonged or repeated contact use gloves. Barrier creams may help to protect exposed skin, they should however not be applied once have come into contact with the product. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.

- Material of gloves:

The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application.

- Penetration time of glove material:

The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

- Eye protection:

Use safety eyewear designed to protect against splash of liquids.

- Body protection:

Working clothes must not consist of textiles which show a dangerous melting behaviour in case of fire. All parts of the skin should be washed after contact.

Stability and reactivity

- Reactivity No further relevant information available.

- Chemical stability No further relevant information available.

- Thermal decomposition / conditions to be avoided: Stable under recommended storage and handling conditions (see section 7 of the SDS).

- Conditions to avoid No further relevant information available.

- Incompatible materials: Keep well away from oxidising agents and strongly alkaline or strongly acid materials in order to avoid exothermic reactions.

- Hazardous decomposition products: Exposition to high temperatures may produce hazardous decomposition products such as: carbon dioxide, carbon monoxide and smoke.

Disposal considerations

Waste treatment methods:

- Recommendation Do not allow to enter drains.

- European waste catalogue 08 03 12: waste ink containing dangerous substances

- Uncleaned packagings: Waste

- Recommendation: Emptied containers should be disposed off into scrap recycling or reconditioning respectively. Not orderly emptied cans and ink remnants are special waste