Registration Dossier

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Guideline study

Data source

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.5 (Surface Tension)
Type of method:
OECD harmonised ring method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent

Results and discussion

Surface tension
Surface tension:
5.71 mN/m
Temp.:
20 °C
Conc.:
423 mg/L

Applicant's summary and conclusion