Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
no
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder

Results and discussion

Vapour pressureopen allclose all
Temp.:
20 °C
Vapour pressure:
ca. 0.04 kPa
Temp.:
40 °C
Vapour pressure:
0.06 kPa
Temp.:
50 °C
Vapour pressure:
0.08 kPa