Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is marketed or used in a non solid or granular form
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 - 18 Oct 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Deviations:
no
GLP compliance:
yes
Type of method:
method to determine freezing temperature
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: MA-3-HO-ANL 1600356
- Expiration date of the lot/batch: 31 Aug 2020
- Purity test date: 05 Feb 2018
- Purity: 96.9%

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature container flushed with nitrogen
- Stability under test conditions: Yes
Melting / freezing pt.:
< -83.5 °C
Atm. press.:
1 014 hPa
Decomposition:
no
Sublimation:
no

At the end of the storage period, the test item was still a liquid. It was concluded that the melting temperature was below storage temperature.

Conclusions:
Melting point < -83.5 °C at 1014 hPa, EU method A.1
Executive summary:

The melting point of MA-3 was determined by placing two subsamples of the test item for 19 hours at -21.1 ± 1.3 °C and at -83.5 ± 1.6 °C respectively. At the end of the storage period, the subsamples remained liquid.

The study was conducted in accordance with EU Method A.1 and was GLP compliant; therefore the study is considered reliable without restrictions.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion