Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
not specified
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
not specified
GLP compliance:
no
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
1,1,2,3,3-pentafluoro-3-(heptafluoropropoxy)prop-1-ene
EC Number:
817-766-4
Cas Number:
91891-42-8
Molecular formula:
C6F12O
IUPAC Name:
1,1,2,3,3-pentafluoro-3-(heptafluoropropoxy)prop-1-ene
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: MA-3 Fo-Id.: 03.353

Results and discussion

Density
Key result
Type:
relative density
Density:
1.615 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

Vpycnometer (20 °C) = 10.278mL (Indication on Pycnometer)

m0 (20 °C) = 16.59g (Mass of Pycnometer)

m2 (20 °C) = 33.19g (Mass of Pycnometer + MA-3)

p (MA-3) = (m2 - m0) / Vpycnometer = 1.615 g/mL

Applicant's summary and conclusion

Conclusions:
The density of MA-3 at 20 °C is 1.615 g/cm³, equivalent to EU Method A.3
Executive summary:

The pycnometer method was used for the determination of the density of the test substance. The study design was equivalent to EU Method A.3 but was not GLP compliant; therefore the study is considered reliable with restrictions.