Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18 Apr 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
Viscosity measured only at 25 °C.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019
Report Date:
2019

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Viscosity
Key result
Temp.:
other: 25 °C
Parameter:
dynamic viscosity (in mPa s)
Value:
134.9

Any other information on results incl. tables

Result/Calculation

Temperature: 25 °C

Apparatus: Ubbelohde viscometer (Viscometer constant 0.175 cSt/s)

 

Flow Time: (1) 682.56 sec, (2) 682.06 sec, (3) 681.41 sec; average 682.01 sec

 

Kinematic Viscosity = 0.175 × 682.01 = 119.35 cSt = 1.19E-4 m²/s

Dynamic viscosity = 119.35 cSt × 1.13 g/cm³ = 134.87 cP = 134.9 mPa*s

 

 

Conclusion

The viscosity of the test item was found to be 134.9 mPa*s at 25 °C