Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Remarks:
Test performed at SHRIRAM INSTITUTE FOR INDUSTRIAL RESEARCH
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Justification for type of information:
In the report, its specified as there are no Particles observed in the range 0.8nm - 6500nm. No where, the actual size of particles is mentioned.

Data source

Reference
Reference Type:
other: Sample sent to SHRIRAM INSTITUTE FOR INDUSTRIAL RESEARCH for analysis
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
yes
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
Laser scattering/diffraction

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Remarks on result:
other: In the report its specified as there are no Particles observed in the range 0.8nm - 6500nm
Particle size
Key result
Percentile:
other: As per the report the Particle size of Karanal is not specified. Its mentioned, there is no particles in the range 0.8nm - 6500nm
Remarks on result:
other: Particle size is not specified in the report

Applicant's summary and conclusion

Conclusions:
No Particles in the range 0.8nm - 6500 nm were oserved for 2-(2,4-Dimethylcyclohex-3-ene-1-yl)-5-methyl-(1-methylpropyl)-1,3-dioxane as per Laser diffraction method.