Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2015
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
equilibrium method closed cup
Dynamic viscosity of test material:
16.53 mm2/s
Key result
Flash point:
208 °C
Atm. press.:
1 007 mBar
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the substance is 208 °C. The substance is not a flammable liquid.

Description of key information

208 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
208 °C

Additional information