Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
03 September 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
- Batch n°: 2712-106
- Analytical purity: 100%
- Expiration date: not indicated
- Storage condition: at room temperature
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
> 300 000
Remarks on result:
other: No sample movement was observed during either test after 40 minutes. The results have therefore been reported as greater than 300 000 mm.s-2
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
> 300 000
Remarks on result:
other: No sample movement was observed during either test after 40 minutes. The results have therefore been reported as greater than 300 000 mm.s-2

Table: Full test results

Run

Temp.

(°C)

Size No

C

Time (sec)

Viscocity (mm2.s-1)

Tested @ 20°C

1

20

11

309.9

> 2400

> 300000

Tested @ 40°C

1

40

11

309.9

> 2400

> 300000

Key: C = viscosity constant; Size no = size of viscometer

No sample movement was observed during either test after 40 minutes. The results have therefore been reported as greater than 300 000 mm.s-2.

Conclusions:
At 20°C the viscosity of the test material was > 300000 mm²/s.
At 40°C the viscosity of the test material was > 300000 mm²/s.

Description of key information

Based on a GLP study according to ISO 3104:1994 and OECD guideline 114 (K1, Dekra, 2018), the viscosity of the test substance was determined to be > 300000 mm²/s at both 20°C and 40°C.

Key value for chemical safety assessment

Additional information