Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 17, 2016 - February 07, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Type of method:
equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2-bis[[(mercaptoacetyl)oxy]methyl]-1,3-propanediyl bis(mercaptoacetate)
EC Number:
233-482-8
EC Name:
2,2-bis[[(mercaptoacetyl)oxy]methyl]-1,3-propanediyl bis(mercaptoacetate)
Cas Number:
10193-99-4
Molecular formula:
C13H20O8S4
IUPAC Name:
3-[(2-sulfanylacetyl)oxy]-2,2-bis({[(2-sulfanylacetyl)oxy]methyl})propyl 2-sulfanylacetate
Test material form:
liquid

Results and discussion

Flash point
Key result
Atm. press.:
1 013 hPa
Remarks on result:
no flash point according to standard method
Remarks:
up to 184°C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item GDMA has no flash point up to 184 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003).





Executive summary: