Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
440/2008
GLP compliance:
yes (incl. QA statement)
Type of method:
dynamic method

Test material

Constituent 1
Chemical structure
Reference substance name:
Fatty acids, vegetable-oil, esters with sterols, mixed with vegetable-oil glycerides
EC Number:
273-605-2
EC Name:
Fatty acids, vegetable-oil, esters with sterols, mixed with vegetable-oil glycerides
Cas Number:
68990-51-2
Molecular formula:
UVCB
IUPAC Name:
(1R,3aS,3bS,7S,9aR,9bS,11aR)-1-[(2R)-5-ethyl-6-methylheptan-2-yl]-9a,11a-dimethyl-1H,2H,3H,3aH,3bH,4H,6H,7H,8H,9H,9aH,9bH,10H,11H,11aH-cyclopenta[a]phenanthren-7-ol; 1-[(9E)-octadec-9-enoyloxy]-3-(octadecanoyloxy)propan-2-yl (9E)-octadec-9-enoate
Test material form:
other: semi solid
Details on test material:
pale yellow
name is the tets report is Phytosteryl Canola Glycerides

Results and discussion

Vapour pressure
Key result
Test no.:
#2
Temp.:
> 40 °C
Remarks on result:
not determinable because of methodological limitations
Remarks:
boiling point of the test item is to high

Any other information on results incl. tables

Please see the attached test report.

Applicant's summary and conclusion

Conclusions:
No vapour pressure could be measured as it was not technically posisble after two attempts (boiling point of the test item is to high). The expected vapour pressure is relatively low according to the testers experts opinion.
Executive summary:

The vapour pressure was measured according to EU Method A.4 (Vapour Pressure). No vapour pressure could be measured as it was not technically posisble after two attempts (boiling point of the test item is to high). The expected vapour pressure is relatively low according to the testers experts opinion.