Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point, other
Remarks:
Testing for solids with low melting point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08032018-09032018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Fatty acids, vegetable-oil, esters with sterols, mixed with vegetable-oil glycerides
EC Number:
273-605-2
EC Name:
Fatty acids, vegetable-oil, esters with sterols, mixed with vegetable-oil glycerides
Cas Number:
68990-51-2
Molecular formula:
UVCB
IUPAC Name:
(1R,3aS,3bS,7S,9aR,9bS,11aR)-1-[(2R)-5-ethyl-6-methylheptan-2-yl]-9a,11a-dimethyl-1H,2H,3H,3aH,3bH,4H,6H,7H,8H,9H,9aH,9bH,10H,11H,11aH-cyclopenta[a]phenanthren-7-ol; 1-[(9E)-octadec-9-enoyloxy]-3-(octadecanoyloxy)propan-2-yl (9E)-octadec-9-enoate
Test material form:
other: semi solid
Details on test material:
pale yellow
name is the tets report is Phytosteryl Canola Glycerides
Specific details on test material used for the study:
Batch number: XP3647
White to very light yellow soft waxy solid.

Results and discussion

Flash point
Key result
Flash point:
264.7 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: Due to nature of the sample, it was warmed to 50C prior to testing.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Flash point is 264.7 oC.
Executive summary:

Flash point is 264.7 oC and the substance is not highly flammable.