Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
flask method

Test material

Constituent 1
Chemical structure
Reference substance name:
3-morpholinopropylamine
EC Number:
204-590-2
EC Name:
3-morpholinopropylamine
Cas Number:
123-00-2
Molecular formula:
C7H16N2O
IUPAC Name:
3-morpholin-4-ylpropan-1-amine
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 7E401
- Storage condition of test material: At room temperature, at 20 ± 5 °C
- Description: Clear and substantially free of foreign matter
- Purity: 99.8 %
- Expiration Date: November 11, 2018

Results and discussion

Water solubility
Key result
Water solubility:
> 1 000 g/L
Remarks on result:
other: The sample was fully miscible and therefore formal testing is not required

Any other information on results incl. tables

Preliminary estimation:

  Mass of sample (mg)   Volume of water in which sample dissolves (mL)   Estimated solubility (g/L)
2000   2  >1000

 

Applicant's summary and conclusion

Conclusions:
According to the preliminary test, the sample was fully miscible and therefore formal testing is not required. Water solubility > 1000 g/L.