Registration Dossier

Administrative data

Endpoint:
thermal stability
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
19/5/2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Deviations:
no
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
150 °C
Sublimation:
no
Transformation products:
no

Applicant's summary and conclusion

Conclusions:
No decomposition or chemical decomposition observed below 150°C.