Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21/6/17
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
yes
Remarks:
A direct reading MKS Baritron Capacitance Manometer Model 628C was substituted for the mercury manometer in the method.
GLP compliance:
not specified
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Vapour pressureopen allclose all
Test no.:
#1
Temp.:
10 °C
Vapour pressure:
80 Pa
Key result
Test no.:
#2
Temp.:
21.1 °C
Vapour pressure:
133.3 Pa
Test no.:
#3
Temp.:
50 °C
Vapour pressure:
813.1 Pa
Test no.:
#4
Temp.:
80 °C
Vapour pressure:
4 372 Pa

Applicant's summary and conclusion

Conclusions:
Vp 133 Pa at 21 °C