Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From September 13, 2017 to September 21, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
75 °C
Atm. press.:
100.5 kPa
Remarks on result:
other: Procedure B (runs 3-5)
Remarks:
method considered to be applicable for the test substance

Full test results:

Temperature

(°C)

Barometric Pressure (kPa)

Ignition?                   Yes (y) / No (n)

Halo/Enlarged test flame?              
Yes (y) / No (n)

Evaluation Run 

25.0 - 90.0

100.9

N

N/A

91.1

100.9

Y

N/A

Run 1

69.0 - 106.0

100.9

N

N/A

107.1

100.9

Y

N/A

Run 2

69.0 - 84.0

100.9

N

N/A

85.0

100.9

Y

N/A

Run 3

63.0 – 74.0

100.5

N

N/A

75.0

100.5

Y

N/A

Run 4

53.0 – 74.0

100.5

N

N/A

75.0

100.5

Y

N/A

Run 5

53.0 – 74.0

100.5

N

N/A

75.9

100.5

Y

N/A

Interpretation of results:
other: CLP criteria not met
Conclusions:
Under the study conditions, flash point of the test susbtance is determined to be 75°C at 100 ± 1 kPa.
Executive summary:

A study was conducted to determine the flash point of the test substance, using closed cup method (Pensky-Martens apparatus), according to EU method A.9 in compliance with GLP. Under the study conditions, flash point of the test substance is determined to be 75°C at 100 ± 1 kPa (Chilworth, 2017).

Description of key information

The flash point of the test substance was determined experimentally using closedcup method, according to EU A.9 Method (Chilworth, 2017)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
75 °C

Additional information