Registration Dossier

Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2004
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2004

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: aqueous solution
Details on test material:
Lexquat AMG-BEO
Lot# D-425-166
active 24% w/w

Results and discussion

Flash point
Flash point:
> 105 °C
Atm. press.:
1 013 hPa
Remarks on result:
no flash point up to 100°C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
flash point > 105C
Executive summary:

The method used was ASTM D3278.

the substance boiled around 103C and the flame was extinguished (by steam?) Above 103C, the flame was still not sustainable despite re-ignition. The study was stopped at 106C with no flash being observed.