Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: visual observation
Reason / purpose for cross-reference:
other: supporting information
Qualifier:
according to guideline
Guideline:
other: 92/69/EEC preliminary method
GLP compliance:
no
Type of method:
other: visual observation
Specific details on test material used for the study:
the substance is supplied in water at 35% active of cocamidopropyl PG-dimonium chloride
Key result
Water solubility:
> 500 000 mg/L
Temp.:
20 °C
pH:
7
Details on results:
the substance is supplied in water at 35% actives. At 50% actives, it is a paste, but still considered to be effectively dissolved in water.
Conclusions:
Miscible in water
Executive summary:

the substance is supplied in water at 35% actives. At 50% actives, it is a paste, ut still considered to be effectively dissolved in water.

Miscible in water

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2004
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Flash point:
> 105 °C
Atm. press.:
1 013 hPa
Remarks on result:
no flash point up to 100°C
Interpretation of results:
GHS criteria not met
Conclusions:
flash point > 105C
Executive summary:

The method used was ASTM D3278.

the substance boiled around 103C and the flame was extinguished (by steam?) Above 103C, the flame was still not sustainable despite re-ignition. The study was stopped at 106C with no flash being observed.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion