Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February from the 06th to the 07th, 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 59 Sieve Analysis
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 170 Dry Sieve Analysis of Water Dispersible Granules
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 169 Tap Density of Water Disperse Granules
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Specific details on test material used for the study:
Test Item was used in its initial form.
Mass median aerodynamic diameter:
100 - 250 µm
Size:
< 45 µm
Distribution:
0.9 %
Remarks on result:
other: based on sum of residues
Size:
< 100 µm
Distribution:
35.5 %
Remarks on result:
other: based on sum of residues
Size:
< 250 µm
Distribution:
60.6 %
Remarks on result:
other: based on sum of residues

TAP DENSITY DETERMINATION

The tap density of the test item was found to be 0.80 g/ml.

Sample mass (W): 80.3 g

Sample volume after dropping (V): 100 ml

Tap density (D): 0.80 g/ml

SIEVE TEST

The particle size distribution of test item was found to be within 45 µm, 1000 µm.

Number of sieves (n): 8

Sample mass (calculated): 128.5 g

Samples mass (m): 128.62 g

Sieve Residue mass gx
(g)
Residue rx
%
Sum of residues Rx
%
Size (μm) Serial No.
< 45 - 3.07 2.4 99.1
45 20111588 12.47 9.7 96.7
63 20111627 28.97 22.5 87.0
100 31121141 32.28 25.1 64.5
250 20111667 33.63 26.1 39.4
500 16111554 16.11 12.5 13.2
1000 20111725 0.87 0.7 0.7
2000 24111027 0.01 0.0 0.0
4000 14111099 0.00 0.0 0.0

gx:the amount of material retained by the sieve x

rx: ratio * 100 of the amount of material retained by the sieve x and sample mass

Rx: the calculated sum of residues on all the x sieves. Therefore the residue Rx on sieve x and the residues on all coarser sieves were summed.

Conclusions:
D50: 100 - 250 µm
Executive summary:

Machine sieving test was carried out using the following test sieves 4, 2, 1 mm, 500, 250, 100, 63 and 45 µm. The analysis has been performed according to the testing procedures described in the following guidelines: CIPAC MT 59 Sieve Analysis, CIPAC MT 170 Dry Anlysis of Water Dispersable Granules and CIPAC MT 169 Tap of Water Dispersable Granules. The particle size distribution of test item was found to be within 45 µm, 1000 µm.

Conclusion

D50: 100 - 250 µm

Description of key information

D50: 100 - 250 µm

Additional information

Sieving test - CIPAC MT 59, 170 and 169