Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experiment start and end date - 16 March 2016; Study completion date - 22 March 2016.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
mass based distribution
Specific details on test material used for the study:
Identification: FAT 40000/I TE Lot: MC 13
Appearance: Orange powder
Mass median aerodynamic diameter:
161.306 µm
Percentile:
D10
Mean:
18.983 µm
Remarks on result:
other: L10 has been determined
Key result
Percentile:
D50
Mean:
161.306 µm
Remarks on result:
other: L50 has been determined
Percentile:
D90
Mean:
424.23 µm
Remarks on result:
other: L90 has been determined
Conclusions:
The median particle size (L50) of test item was found to be 161.306 µm.
Executive summary:

The particle size of test item was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Laser diffraction method was used for this purpose.

Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 18.983, 161.306 and 424.230 µm, respectively. Hence, the median particle size (L50) of test item was determined to be 161.306 µm.

Description of key information

The median particle size (L50) of test item was determined to be 161.306 µm.

Additional information

The particle size of test item was determined in a study conducted according to the guidelines CIPAC MT 187 and ISO 13320 -1. Laser diffraction method was used for this purpose.

Based on the findings of the study, L10, L50 and L90 for the test substance were determined to be 18.983, 161.306 and 424.230 µm, respectively. Hence, the median particle size (L50) of test item was determined to be 161.306 µm.