Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
plate method

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2-bis({[3-(4-ethylpiperazin-1-yl)propanoyl]oxy}methyl)butyl 3-(4-ethylpiperazin-1-yl)propanoate
EC Number:
700-404-3
Cas Number:
127929-37-7
Molecular formula:
C33H62N6O6
IUPAC Name:
2,2-bis({[3-(4-ethylpiperazin-1-yl)propanoyl]oxy}methyl)butyl 3-(4-ethylpiperazin-1-yl)propanoate

Results and discussion

Surface tension
Surface tension:
>= 45.55 - <= 45.89 mN/m
Temp.:
20.2 °C
Conc.:
1 g/L

Any other information on results incl. tables

During a certain period of time, no significant changes in the surface tension were detected. In dependence on time and temperature, values between 43.54 and 46.11 mN/m were recorded showing no significant variations. As the determined surface tension of B 1061 was below 60 mN/m, the test item can be classified as surface active.

Applicant's summary and conclusion

Executive summary:

The surface tension of an aqueous solution of B 1061 was determined as

45.72 +- 0.17 mN/m at 20.2 °C

One additional measurement was performed for verification (after 59 minutes). No significant changes and thus no significant dependence on time and temperature were observed.

As these values are below than 60 mN/m, the test item B 1061 was classified as surface active.

The surface tension of the negative control lay within the accepted range.