Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental result using standard methods of analysis

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 122 (Determination of pH, Acidity and Alkalinity)
Principles of method if other than guideline:
The pH determination of test chemical was done as per the test guideline OECD Guideline 122 (Determination of pH, Acidity and Alkalinity). The pH of the test solution was determined with the help of pH meter.
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Oxacycloheptadec-10-en-2-one
EC Number:
249-120-7
EC Name:
Oxacycloheptadec-10-en-2-one
Cas Number:
28645-51-4
Molecular formula:
C16H28O2
IUPAC Name:
oxacycloheptadec-10-en-2-one
Test material form:
liquid
Details on test material:
- Name of test material (as cited in study report): Ambrettolide
- Molecular formula : C16H28O2
- Molecular weight : 252.395 gram/mol
- Substance type: Organic
- Smiles : C1C=CCCCCCCOC(CCCCCC1)=O
- InChI : 1S/C16H28O2/c17-16-14-12-10-8-6-4-2-1-3-5-7-9-11-13-15-18-16/h1,3H,2,4-15H2/b3-1-
- Physical state: Liquid
- Purity: No data available
- Impurities (identity and concentrations): No data available

Results and discussion

pH value
Key result
pH value:
6.3
Temp.:
30.1 °C
Concentration:
1 other: % w/v
Remarks on result:
other: No other detail available

Any other information on results incl. tables

TEST RESULTS :

Method Details

Observations

Remarks if, any

Guideline

OECD 122

 

 

Method

 

pH Meter

 

Principle of method

 

 

 

 

 

 

 

A pH meter is essentially a voltmeter with high input impedance which measures the voltage of an electrode sensitive to the hydrogen ion concentration, relative to another electrode which exhibits a constant voltage.

 

Temperature of 1% w/v test solution

-

30.1 °C

pH (RESULT)

 

-

6.3

Inference

1.   Acidic

2.   Basic

3.   Neutral

 

Acidic

 

Applicant's summary and conclusion

Conclusions:
The pH of 1% w/v aqueous solution of the test chemical was determined to be 6.3 at 30 °C
Executive summary:

The pH determination of test chemical was done following OECD Guideline 122 (Determination of pH, Acidity and Alkalinity). pH of 1% w/v aqueous solution was measured with the help of pH meter and it was observed to be 6.3 at 30°C. Thus, based on this pH, test chemical is considered to be acidic in nature.