Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-like

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Viscosity
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
3 030

Applicant's summary and conclusion

Conclusions:
Dynamic Viscosity (20°C): 3030 mPa*s