Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-07-07 to 2015-07-27
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2003
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
EPA OPPTS 830.6315 (Flammability)
Version / remarks:
1996
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
114 °C
Atm. press.:
1 013 hPa

Table 1 Preliminary Test

Amount of test item g

Temperature °C

Ignition +/-

Air pressure hPa

66.85

114.0

+

999.5

Table 1 Main Test

Amount of test item g

Temperature °C

Ignition +/-

Air pressure hPa

Corrected flash point °C

63.54

114.0

+

997.9

114.38

65.42

114.0

+

997.5

114.39

Interpretation of results:
GHS criteria not met
Conclusions:
The test item has a flash point of 114.0 °C (average corrected and rounded down to the nearest multiple of 0.5 °C) according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003).
Executive summary:

A study was conducted according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003) to determine flash point of the test item using the Pensky-Martens closed cup method. The start temperature for the main test (114 °C) was chosen based on preliminary test results. Approx. 63.5 g of the test item was filled in the cup and heated to the estimated temperature. The measured flash point at atmospheric pressure was corrected to a standard pressure of 1013 hPa. The flash point was determined to be at 114.4 °C (corrected to the ambient pressure). Thus, the flash point of the test item was determined to be 114 °C (corrected and rounded down to the nearest multiple of 0.5 °C) at 997.9 – 997.5 hPa.

Description of key information

The test item has a flash point of 114.0 °C (average corrected and rounded down to the nearest multiple of 0.5 °C) according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
114 °C

Additional information

A study was conducted according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 2719 (2003) to determine flash point of the test item using the Pensky-Martens closed cup method. The start temperature for the main test (114 °C) was chosen based on preliminary test results. Approx. 63.5 g of the test item was filled in the cup and heated to the estimated temperature. The measured flash point at atmospheric pressure was corrected to a standard pressure of 1013 hPa. The flash point was determined to be at 114.4 °C (corrected to the ambient pressure). Thus, the flash point of the test item was determined to be 114 °C (corrected and rounded down to the nearest multiple of 0.5 °C) at 997.9 – 997.5 hPa.