Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning time (test type not further specified)
Burning time:
> 2 min

Preliminary test

Buming time > 2 min, no meta! powder. Therefore, the preliminary screening test is negative.

Maintest:

Omitted due to result of preliminary test.

Interpretation of results:
GHS criteria not met
Conclusions:
According to the result of the preliminary test the test substance is not considered as a flammable solid. The result does not lead to a classification.

Description of key information

- Not highly flammable upon ignition

- No pyrophoric properties

- Does not liberate flammable gases on contact with water.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The determination was performed according to UN Test N.1.

- Upon ignition the test substance was burned over 2 min.

- Based on chemical structure and experience in handling and use of substance the pyrophoric properties and the flammability in contact with water are not to be expected

Justification for classification or non-classification

- Upon ignition the test substance was burned over 2 min.

- Based on chemical structure and experience in handling and use of substance the pyrophoric properties and the flammability in contact with water are not to be expected.

It can be concluded that the substance is not considered to be classified as a flammable material.