Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
8 December 2009 - 17 December 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
The study report includes a certificate of GLP compliance issued by the MHRA.
Type of method:
HPLC estimation method
Media:
soil
Radiolabelling:
no
Details on study design: HPLC method:
EQUIPMENT
- Apparatus: Agilent 1200 Series Liquid Chromatograph
- Type, material and dimension of analytical (guard) column: Hypersil CPS (25 cm x 4.6 mm internal diameter)
- Column temperature: 25°C
- Flow rate: 1.0 ml/minute
- Injection volume: 20 µl
- Detection system: UV set at 210 nm

MOBILE PHASES
- Type: Acetonitrile:water (55:45 v/v)
- Experiments with additives carried out on separate columns: N/A
- pH: no data
- Solutes for dissolving test and reference substances: acetonitrile:water (3:1 v/v)

DETERMINATION OF DEAD TIME
- Method: An internal deadtime standard (IDS) was used - formamide.

REFERENCE SUBSTANCES
- Identity: Acetanilide, Nitrobenzene, Naphthalene, 2-Methylnaphthalene, Anthracene, DDT

DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 20µL of a solution at 1.6g/L
- Quantity of reference substances: 20µL of a solution at 1.6g/L
- Intervals of calibration: no data

REPETITIONS
- Number of determinations: 2

EVALUATION
- Calculation of capacity factors k': yes
- Calculation of retention times:yes
- Determination of the log Koc value: yes
Key result
Type:
log Koc
Value:
1.2
Temp.:
25 °C
Details on results (HPLC method):
- Retention times of reference substances used for calibration:
Deadtime standard - 2.90 minutes
Acetanilide - 3.42 minutes
Nitrobenzene - 4.10 minutes
Napthalene - 4.72 minutes
2-Methylnapthalene - 4.98 minutes
Anthracene - 5.50 minutes
DDT - 7.87 minutes
- Details of fitted regression line (log k' vs. log Koc): calculated regression - log10Koc = 4.62log10k + 4.37
- Average retention data for test substance: retention time for substance = 3.501 minutes; calculated log10Koc = 1.2
Validity criteria fulfilled:
yes
Conclusions:
MMB-Ac was found to have log Koc value of 1.2. at 25°C.

Description of key information

MMB-Ac was found to have log Koc value of 1.2. at 25°C, which equalizes to a Koc value of 15.8 L/kg.

Key value for chemical safety assessment

Other adsorption coefficients

Type:
log Kp (solids-water in soil)
Value in L/kg:
1.2
at the temperature of:
25 °C

Additional information