Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Version / remarks:
1984
GLP compliance:
no
Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
The sludge was coarsely sieved, centrifuged, the supernatant liquid phase decanted, the solid material resuspended in tap water and again centrifuged. This procedure was repeated a further 2 times. An aliquot of the final sludge suspension was weighed, dried and the ratio of wet sludge (ml) to its dry weight (g) determined. Based on this ratio, a volume of washed sludge suspension corresponding to 4 g dry material were made up with Soerensen buffer (pH = 7) to 1 l. To that mixture, 50 ml OECD recommended synthetic sewage feed were added. Thereafter, the sludge was incubated overnight at 20-25 °C under aeration.
Water media type:
freshwater
Total exposure duration:
3 h
Test temperature:
22 °C
Dissolved oxygen:
aeration 0.2 l/min
Nominal and measured concentrations:
10, 100 mg/l
Reference substance (positive control):
yes
Remarks:
3,5-dichlorophenol
Duration:
3 h
Dose descriptor:
IC50
Effect conc.:
> 100 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Details on results:
100 - (2Rs /(Rc1 + Rc2) × 100 = percent inhibition
Rs = oxygen consumption rate at tested concentration of test article
Rc1 = oxygen consumption rate, control 1
Rc2 = oxygen consumption rate, control 2
Results with reference substance (positive control):
IC50 = 9 mg/l (i.e. between 5 and 30 mg/l)
Validity criteria fulfilled:
yes
Remarks:
variance between controls 11.9 %; inhibitory effect of positive control within 5 and 30 mg/l.
Conclusions:
IC50 (3h) > 100 mg/l
Executive summary:

The inhibitory effect of test substance on aerobic waste-water bacteria was investigated in a respiration test.

No inhibition was seen up to 100 mg/l, thus IC50 > 100 mg/l upon a 3 -hour exposure.

Positive control 3,5 -dichlorophenol showed an IC50 = 9 mg/l.

Description of key information

IC50 (3h) > 100 mg/l

Key value for chemical safety assessment

Additional information

OECD guideline 209.

No inhibition of the respiration rate was seen upon a 3 -hour exposure of an activated sludge at the highest tested concentration of 100 mg/l.