Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2019

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
flask method

Test material

Constituent 1
Chemical structure
Reference substance name:
Piperonyl acetate
EC Number:
206-312-5
EC Name:
Piperonyl acetate
Cas Number:
326-61-4
Molecular formula:
C10H10O4
IUPAC Name:
(2H-1,3-benzodioxol-5-yl)methyl acetate
impurity 1
Chemical structure
Reference substance name:
Piperonyl alcohol
EC Number:
207-808-4
EC Name:
Piperonyl alcohol
Cas Number:
495-76-1
Molecular formula:
C8H8O3
IUPAC Name:
1,3-benzodioxol-5-ylmethanol
Specific details on test material used for the study:
Batch no.: 18040126
Appearance: colourless liquid
Purity: 99.80% (GC)
Homogeneity: homogeneous
Expiry date: 23. May 2020
Storage: room temperature (20 ± 5°C)
Density: 1.237 g/cm3
Storage: the test item was stored in a closed vessel at room temperature (20 ± 5°C), dry, in the dark.

Results and discussion

Water solubility
Key result
Water solubility:
ca. 1.19 g/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
>= 4.21 - <= 4.28

Any other information on results incl. tables

*   Deviations from the Study Plan

The following deviations from the study plan were documented; in the preliminary test the nominal load 200 g/L was tested instead of 20 g/L. This was considered as uncritical as an excess of the test item was necessary in the preliminary test and a higher excess was used. The deviation was assessed and signed by the study director on 02. Apr. 2019.

The calibration was not renewed although the recovery rate of QC sample was higher than 115 %. This was considered as uncritical as a fresh prepared QC sample was measured and the recovery rate lay in the range of 100±15 %. The deviation was assessed and signed by the study director on 09. Apr. 2019. 

Applicant's summary and conclusion

Conclusions:
According to OECD 105, the water solubility of the test item is:
1.19 ± 0.08 g/L at 20.0 ± 0.5 °C and pH 4.21 – 4.28
= 1.19 ± 0.08 kg/m3(SI units)
(mean value ± standard deviation)