Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187: Particle Size Analysis by Laser Diffraction ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
other: dry dispersion
Specific details on test material used for the study:
Identification: FAT 11127/E TE Lot. 2024 (Thailand)
Appearance: Dark blue powder
Mass median aerodynamic diameter:
ca. 73.152 µm
Key result
Percentile:
D50
Mean:
ca. 73.152 µm
Remarks on result:
other: Std deviation not specified
Percentile:
D10
Mean:
16.595 µm
Remarks on result:
other: Std deviation not specified
Percentile:
D90
Mean:
301.94 µm
Remarks on result:
other: Std deviation not specified
Conclusions:
The median particle size (L50) of FAT 11127/E TE was 73.152 µm, whereas L10 and L90 were 16.595 µm and 301.940 µm, respectively.
Executive summary:

The particle size distribution of FAT 11127/E TE was evaluated in a study conducted according to 'CIPAC MT 187: Particle Size Analysis by Laser Diffraction' and 'ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods'. The median particle size (L50) of FAT 11127/E TE was 73.152 µm, whereas L10 and L90 were 16.595 µm and 301.940 µm, respectively.

Description of key information

The particle size distribution of FAT 11127/E TE was evaluated in a study conducted according to 'CIPAC MT 187: Particle Size Analysis by Laser Diffraction' and 'ISO 13320-1: Particle Size Analysis – Laser Diffraction Methods'. The median particle size (L50) of FAT 11127/E TE was 73.152 µm, whereas L10 and L90 were 16.595 µm and 301.940 µm, respectively.

Additional information