Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 16 January 2018, Experimental completion date: 11 May 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
N-octylpyridin-4-amine
EC Number:
265-019-0
EC Name:
N-octylpyridin-4-amine
Cas Number:
64690-19-3
Molecular formula:
C13H22N2
IUPAC Name:
N-octylpyridin-4-amine

Results and discussion

Densityopen allclose all
Key result
Type:
density
Density:
1 060 kg/m³
Temp.:
20 °C
Key result
Type:
relative density
Density:
1.06
Temp.:
20 °C

Any other information on results incl. tables

Calibration

The pressure readings and the calculated volume for the reference and sample cells are shown in the following table:

Table 2

Determination

P1(psig)

P2 (psig)

P3(psig)

P4(psig)

Reference Cell Volume (cm3)

Sample Cell Volume (cm3)

1

18.156

6.876

17.679

8.757

90.983

149.256

2

17.518

6.631

17.960

8.897

90.759

149.012

3

17.231

6.521

17.166

8.500

90.806

149.138

 

Mean reference cell volume : 90.849 cm3

Mean sample cell volume : 149.135 cm3

As the reference cell volume and sample cell volume were within the defined tolerance (90.953 ± 1.0 cm3and 149.225 ± 1.0 cm3for the reference and sample cell volumes respectively) the gas comparison pycnometer was therefore considered acceptable for use.

Sample

The pressure readings, calculated volumes and density values obtained for the test item are shown in the following table:

Table 3

Determination

Replicate

P1(sample)(psig)

P2(sample)(psig)

Volume (cm3)

Density (kg/m3)

Mean Density (kg/m3)

1

A

17.304

7.430

28.4

1.06 x 103

1.06 x 103

B

17.378

7.463

28.4

1.05 x 103

C

17.472

7.502

28.4

1.06 x 103

2

A

17.958

7.846

32.0

1.05 x 103

1.06 x 103

B

17.475

7.633

32.0

1.06 x 103

C

17.568

7.672

32.0

1.06 x 103

Mean density : 1.06 x 103 kg/m3

Relative density : 1.06

Temperature : 20.0 ± 0.5 °C

Discussion

Duplicate determinations were performed to ensure a reproducibility of less than ± 20 kg/m3was obtained.

Conclusion

The density of the test item has been determined to be 1.06 x 103 kg/m3at 20.0 ± 0.5 °C and a relative density of 1.06.

Applicant's summary and conclusion

Conclusions:
The density of the test item has been determined to be 1.06 x 10^3 kg/m3at 20.0 ± 0.5 °C and a relative density of 1.06.