Registration Dossier

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 17, 2016 - June 27, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item THIOCURE® PETMA could not be ignited applying a flame as ignition source for at least 2 minutes. The test item melted.
Executive summary:

The test item THIOCURE®PETMA could not be ignited applying a flame as ignition source for at least 2 minutes. The test item melted.

Description of key information

Since the melting range of the test item was between 30 and 50 °C, the determination of the self-heating was not necessary.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification