Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January 7th, 2008 - July 14th, 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
- Analytical purity: 82.3%
- Purity test date: Not available
- Lot/batch No.: GN-8
- Expiration date of the lot/batch: Not available
- Appearance: Amber coloured, extremely viscous liquid
- Storage: In the dark at room temperature
- Additional information on test material used for the study: It was attempted to purify the substance to a purity of >80% by using an alternative synthetic route, as opposed to the usual commercial route of synthesis which results in a purity of the substance of approximately 40% in water. This alternative synthetic route generated the substance at 82.3% purity, however it also generated an impurity (methanol at 4.0%) which is not present in the commercial substance. Based on the classification and labelling of methanol, it is considered that this additional impurity would not have an influence on any of the endpoints discussed in this dossier other than the acute oral toxicity study. Therefore all studies (including the one covering this endpoint) contained in this dossier (other than the acute oral toxicity study) were conducted on the 82.3% pure substance containing the 4.0% methanol impurity. The acute oral toxicity study has been conducted on the commercially generated substance at a purity of approximately 40% in water.
Key result
Auto-ignition temperature:
>= 263 - <= 271 °C
Atm. press.:
>= 992.5 - <= 1 029.2 hPa
Conclusions:
The test material was determined to have an auto-ignition temperature of 268 ± 5°C.
Executive summary:

The auto-ignition temperature of the test material was measured in a GLP-compliant study performed in accordance with EU Method A.15. The auto-ignition temperature of the test material was determined to be 268°C ± 5°C.

Description of key information

The auto-ignition temperature of the test material was measured in a GLP-compliant study performed in accordance with EU Method A.15. The auto-ignition temperature of the test material was determined to be 268°C ± 5°C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
268 °C

Additional information

The auto-ignition temperature of the test material was determined in a GLP-compliant study performed in accordance with standard methods, without deviations. The study is considered as reliable (Klimisch

1) and is selected as a key study for the endpoint.