Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 July 2009 to 15 August 2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: GB/T 261-2008
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: SH-3B Automatic flash point tester
Key result
Flash point:
161 °C
Remarks on result:
other: Atm. pressure not specified
Interpretation of results:
other: Not classified in accordance with EU criteria
Conclusions:
Under the conditions of the study the flash point of the test material was 161ºC (closed cup).
Executive summary:

The flash point of the test material was investigated in accordance with GB/T 261-2008 under GLP conditions. Under the conditions of the study the flash point of the test material was 161°C (closed cup).

Description of key information

Under the conditions of the study the flash point of the test material was 161°C (closed cup).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
161 °C

Additional information