Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to OECD / EU guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2006

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
0.11 Pa

Applicant's summary and conclusion

Conclusions:
3,4'-Dichlorodiphenylether showed a vapour pressure of 0.11 Pa at 25 °C in a study according to EU testing method A.4.