Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Principles of method if other than guideline:
Particle size distribution was obtained by Malvern Mastersizer 2000 coupled with Scirocco instrument, working in the range of 0.02 um to 2000 um for dry analysis.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
6-cyclohexyl-1-hydroxy-4-methylpyridin-2(1H)-one, compound with 2-aminoethanol (1:1)
EC Number:
255-464-9
EC Name:
6-cyclohexyl-1-hydroxy-4-methylpyridin-2(1H)-one, compound with 2-aminoethanol (1:1)
Cas Number:
41621-49-2
Molecular formula:
C12H17NO2.C2H7NO
IUPAC Name:
6-cyclohexyl-1-hydroxy-4-methylpyridin-2(1H)-one, compound with 2-aminoethanol (1:1)
Test material form:
solid: particulate/powder

Results and discussion

Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
3.59 µm
Distribution:
10 %
No.:
#2
Size:
52.13 µm
Distribution:
50 %
No.:
#3
Size:
176.48 µm
Distribution:
90 %

Applicant's summary and conclusion