Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
no guideline required
Principles of method if other than guideline:
Theoretical consideration, based on chemical structure of the components in the formulation.
GLP compliance:
no
Remarks:
(not relevant)

Test material

Constituent 1
Chemical structure
Reference substance name:
N,2-dimethyl-N-phenylbutyramide
EC Number:
282-817-4
EC Name:
N,2-dimethyl-N-phenylbutyramide
Cas Number:
84434-18-4
Molecular formula:
C12H17NO
IUPAC Name:
N,2-dimethyl-N-phenylbutanamide
impurity 1
Reference substance name:
Unknown impurities
Molecular formula:
Unknown
IUPAC Name:
Unknown impurities
Test material form:
liquid
Specific details on test material used for the study:
Commercial name: Gardamide
Givaudan Code No.: 1390623
Chemical Nature: N,2-dimethyl-N-phenylbutanamide
Molecular weight: 191.27 g/mol
Empirical formula: C12H17NO

Results and discussion

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Gardamide is incapable of causing fire or enhance the risk of fire when in contact with combustible material.
Executive summary:

From the structural formula of Gardamide, it can be concluded that the substance is not an oxidising substance. The substance does not have the functional groups associated with oxidising properties. The oxygen present in the molecule is linked to carbon and hydrogen atoms only.