Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 939-415-5 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Vapour pressure
Administrative data
Link to relevant study record(s)
- Endpoint:
- vapour pressure
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2012-10-02 to 2012-12-03
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.4 (Vapour Pressure)
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 104 (Vapour Pressure Curve)
- GLP compliance:
- yes
- Type of method:
- effusion method: vapour pressure balance
- Temp.:
- 25 °C
- Vapour pressure:
- 0 Pa
- Conclusions:
- The vapour pressure of the test item has been determined to be 3.2E-06 Pa at 25°C
- Executive summary:
Method
The determination was carried out using a procedure designed to be compatible with Method A4 Vapour Pressure of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 104 of the OECD Guidelines for Testing of Chemicals, 23 March 2006
Conclusion
The vapour pressure of the test item has been determined to be 3.2E-06 Pa at 25 °C
- Endpoint:
- vapour pressure
- Type of information:
- (Q)SAR
- Adequacy of study:
- supporting study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Accepted calculation method. SPARC online calculator.
- Justification for type of information:
- QSAR prediction: migrated from IUCLID 5.6
- Principles of method if other than guideline:
- Calculation based on SPARC online calculator http://ibmlc2.chem.uga.edu/sparc/, University of Georgia, USA.
- GLP compliance:
- no
- Remarks:
- Calculation
- Type of method:
- other: estimated by calculation
- Temp.:
- 20 °C
- Vapour pressure:
- 0 Pa
- Remarks on result:
- other: Calculation for C30H56O6
- Temp.:
- 20 °C
- Vapour pressure:
- 0 Pa
- Remarks on result:
- other: Calculation for C36H68O6
- Endpoint:
- vapour pressure
- Type of information:
- (Q)SAR
- Adequacy of study:
- supporting study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Accepted calculation method SPARC online calculator.
- Justification for type of information:
- QSAR prediction: migrated from IUCLID 5.6
- Principles of method if other than guideline:
- Calculation based on SPARC online calculator http://ibmlc2.chem.uga.edu/sparc/, University of Georgia, USA.
- GLP compliance:
- no
- Remarks:
- Calculation
- Type of method:
- other: estimated by calculation
- Temp.:
- 20 °C
- Vapour pressure:
- 0 Pa
- Remarks on result:
- other: Calculated for C25H44O8
- Temp.:
- 20 °C
- Vapour pressure:
- 0 Pa
- Remarks on result:
- other: 7.38E-16 Pa calculated for C33H60O8
- Endpoint:
- vapour pressure
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: analogue substance
- Justification for type of information:
- Determination of vapour pressure is not required because available data indicate that structural variation does not influence test results or adverse effect profile (see read-across and category justifications attached in Section 13).
- Reason / purpose for cross-reference:
- read-across source
- Key result
- Temp.:
- 25 °C
- Vapour pressure:
- 0 Pa
Referenceopen allclose all
The test item did not change in appearence under the conditions used in the determination.
Description of key information
The vapour pressure of the analogue substance was determined to be 3.2E-06 Pa at 25 °C.
Key value for chemical safety assessment
- Vapour pressure:
- 0 Pa
- at the temperature of:
- 25 °C
Additional information
The vapour pressure of the analogue substance was determined to be 3.2E-06 Pa at 25 °C.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.