Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013-03-06 to 2013-04-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD guideline 114 and EN ISO 12058-1 (2002) in a GLP certified testing facility.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: EN ISO 12058-1
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
forced ball viscometer (dynamic)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
401.054

All measured values and the corresponding calculation results are given in the following table:

 

First Determination

 

Temperature

Falling Time

Total Time

Viscosity

Measurement

[°C]

[min]

 [s]

[s]

[mPa*s]

No. 1

20.00

1

24.59

84.59

399.3858

No. 2

20.00

1

24.63

84.63

399.5747

No. 3

20.00

1

24.72

84.72

399.9996

Mean

 

 

 

84.65

399.6534

Standard Deviation

 

 

 

0.07

0.3144

RSD

 

 

 

 

0.08 %

 

Second Determination

 

Temperature

Falling Time

Total Time

Viscosity

Measurement

[°C]

[min]

 [s]

[s]

[mPa*s]

No. 1

20.02

1

25.28

85.28

402.6436

No. 2

20.02

1

25.32

85.32

402.8325

No. 3

20.04

1

25.12

85.12

401.8882

Mean

 

 

 

85.24

402.4548

Standard Deviation

 

 

 

0.11

0.4997

RSD

 

 

 

 

0.12 %

Conclusions:
The viscosity of 400112 was determined as 401.054 ± 1.579 mPa * s at 20.00 ± 0.04 °C.
Executive summary:

The viscosity of 400112 was determined according to OECD guideline 114 and EN ISO 12058-1 (2002) in a GLP certified testing facility.

The viscosity was determined as 401.054 ±1.579 mPa*s which is the mean of two determinations with three individual measurements each. Precision of the value is given as standard deviation of all six individual measurements. As the measured RSD was 0.39 %, the validity criterion for the used ball was met. Measurements were performed at 20.00±0.04 °C.

No observations arousing doubts concerning the accuracy of the results and the validity of the study were made.

Description of key information

The viscosity of 400112 was determined as 401.054 ± 1.579 mPa * s at 20.00 ± 0.04 °C. 

Key value for chemical safety assessment

Viscosity:
401.054 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

The viscosity of 400112 was determined according to OECD guideline 114 and EN ISO 12058-1 (2002) in a GLP-certified testing facility.

The viscosity was determined as 401.054 ±1.579mPa*s which is the mean of two determinations with three individual measurements each. Precision of the value is given as standard deviation of all six individual measurements. As the measured RSD was 0.39 %, the validity criterion for the used ball is met. Measurements were performed at 20.00±0.04 °C.

No observations arousing doubts concerning the accuracy of the results and the validity of the study were made.