Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experiment and study completion date - 27 September 2019.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Test Item: FAT 75637/A
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Safety Pre-Test: A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed signs of ignition.

Preliminary screening test: The test item was heated with the flame of a teclu burner. Glowing was observed during heating. An ignition occurred within two minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
No ignition was observed throughout the course of the test. FAT 75637/A is considered to be not highly flammable!
Executive summary:

This study was performed in order to determine the flammability FAT 75637/A according to EU method A.10. For a safety Pre-Test a small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed signs of ignition. For the preliminary screening test the test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. No ignition was observed throughout the course of the test. The test item FAT 75637/A should be considered as not highly flammable!

Description of key information

This study was performed in order to determine the flammability FAT 75637/A according to EU method A.10. For a safety Pre-Test a small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed signs of ignition. For the preliminary screening test the test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. No ignition was observed throughout the course of the test. The test item FAT 75637/A should be considered as not highly flammable!

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

FAT 75637/A was found to be not flammable in the study performed according to EU Method A.10, hence it does not warrant classification in accordance with CLP (Regulation EC No. 1272/2008).