Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
solid
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 20, 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Atm. press.:
1 013 hPa
Remarks on result:
no flash point according to standard method
Remarks:
No flash point dertermined up to 100°C. Heating continued up to 250°C with no flash point determined.
Interpretation of results:
other: No flash point obtained
Conclusions:
No flash point was obtained for solid/crystaline violuric acid using test method ISO 3679:2015
Executive summary:

Solid/crystaline violuric acid was tested in accordance to test method ISO 3679:2015 (EC Method A.9). No flash point was determined.

Description of key information

Solid/crystaline violuric acid was tested in accordance to test method ISO 3679:2015 (EC Method A.9). No flash point was determined.

Key value for chemical safety assessment

Additional information

No flash point was obtained for solid/crystaline violuric acid using test method ISO 3679:2015