Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Heptanoyl chloride
EC Number:
219-775-3
EC Name:
Heptanoyl chloride
Cas Number:
2528-61-2
Molecular formula:
C7H13ClO
IUPAC Name:
heptanoyl chloride
Details on test material:
- Name of test material (as cited in study report): Heptane acid chloride
- Analytical purity: >= 98,5% - <=99,5%
- Lot/batch No.: LJ 10492/027

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
240 °C
Atm. press.:
1 013.25 hPa
Remarks on result:
other:

Any other information on results incl. tables

Results





























Test run no.lowest temperature
[°C]
quantity of sample
[mL]
ignition delay time
[s]
12450.0721
22460.0926
32440.0928

 


The tests were performed at an atmospheric pressure of 995 mbar - 1006 mbar.


 


From these test runs a corrected* auto-ignition-temperature of 240 °C results.


 


* Correction performed according to EN 14522.

Applicant's summary and conclusion