Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: OECD Guideline 104
GLP compliance:
yes (incl. QA statement)
Type of method:
dynamic method

Test material

Constituent 1
Chemical structure
Reference substance name:
Heptanoyl chloride
EC Number:
219-775-3
EC Name:
Heptanoyl chloride
Cas Number:
2528-61-2
Molecular formula:
C7H13ClO
IUPAC Name:
heptanoyl chloride
Details on test material:
- Name of test material (as cited in study report): Heptanoyl chloride
- Analytical purity: 99.6% (GC-area-%, given by the sponsor)
- Lot/batch No.: B095

Results and discussion

Boiling point
Key result
Boiling pt.:
175.11 °C
Atm. press.:
1 013.25 hPa
Remarks on result:
other: Interpolation of vapour pressure curve. The vapour pressure was determined by dynamic method according to OECD Guideline 104.

Any other information on results incl. tables

Results:






























































































Temperature
[t/°C]
Vapour Pressure
[p/hPa]
 MeasurementCalculation
17.711.000.994
27.482.002.001
33.583.003.010
41.675.005.015
47.286.997.010
53.459.959.966
66.6219.9920.030
74.8529.9829.978
85.9849.9849.891
93.8370.0169.860
102.5599.9799.533
121.22199.9199.41
133.21300.0299.31
149.69499.7500.31
161.43699.4701.53
175.111011.71013.34

 


The regression of the results leads with a mean deviation of 0.24 % to the following equation:
In(p/hPa) =16.8481 - 3801.78 / (207.86 + t/°C)


 


The normal boiling temperature was obtained by intrapolation from the vapour pressure curve.


 


The test item is liquid in the temperature range used for the vapour pressure measurements.


 


 


 


 


 


 


 


 


 

Applicant's summary and conclusion