Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 59 Sieve Analysis
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 170 Dry Sieve Analysis of Water Dispersible Granules
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 169 Tap Density of Water Dispersible Granules
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
Mass median aerodynamic diameter:
> 100 - < 1 000 µm
No.:
#1
Size:
> 100 µm
Distribution:
97 %
No.:
#1
Size:
> 45 µm
Distribution:
99.9 %

DETERMINATION OF TAP DENSITY

Sample mass (W): 80.1 g

Sample volume after dropping (V): 89 ml

Tap density (D): 0.90 g/ml

SIEVE TEST

N. of sieves: 8

Sample mass (m, calculated): 144.0 g

Sample mass (weighed): 144.0 g

Sieve Residue mass gx (g) Residue rx (m/m) % Sum of residues Rx (m/m) %
Size (µm) Serial No.
<45 (receiver pan) - 0.00 0.0 99.9
45 20111588 0.14 0.1 99.9
63 20111627 4.04 2.8 99.8
100 31121141 39.02 27.1 97.0
250 20111667 50.99 35.4 69.9
500 16111554 40.24 27.9 34.5
1000 20111725 8.61 6.0 6.5
2000 24111027 0.74 0.5 0.6
4000 14111099 0.07 0.1 0.1

gx: the amount of material retained by the sieve x

rx: ratio * 100 of the amount of material retained by the sieve x and sample mass

Rx: the calculated sum of residues on all the x sieves. Therefore the residue Rx on sieve x and the residues on all coarser sieves were summed.

Conclusions:
Particle size distribution: 100 - 1000 µm
Executive summary:

Machine sieving test was carried out using the following test sieves 4, 2, 1 mm, 500, 250, 100, 63 and 45 µm. The analysis has been performed according to the testing procedures described in the following guidelines: CIPAC MT 59 Sieve Analysis, CIPAC MT 170 Dry Anlysis of Water Dispersable Granules and CIPAC MT 169 Tap of Water Dispersable Granules. 

Conclusion

The particle size distribution of test item was found to be: 100 - 1000 µm.

Description of key information

Particle size distribution: 100 - 1000 µm

Additional information

CIPAC MT 59, 170 and 169 - sieving test