Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 August 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Key result
Type:
relative density
Density:
1.308
Temp.:
20 °C
Remarks on result:
other: untis for relative denisty are not applicable
Conclusions:
Under the conditions of the study, the relative density of the test material was determined to be 1.308.
Executive summary:

The relative density of the test material was determined by the pycnometer method and in line with standardised guideline EU Method A.3 and under GLP.

Under the conditions of the study, the relative density of the test material was determined to be 1.308.

Description of key information

Under the conditions of the study, the relative density of the test material was determined to be 1.308.

Key value for chemical safety assessment

Relative density at 20C:
1.308

Additional information

The relative density of the test material was determined by the pycnometer method and in line with standardised guideline EU Method A.3 and under GLP.

Under the conditions of the study, the relative density of the test material was determined to be 1.308.